Exhaust Flap Vacuum Diaphragm, Checking
Exhaust Flap Vacuum Diaphragm, Checking
Special tools, testers and auxiliary items required
• Hand Vacuum Pump (VAS 6213)
Procedure
- Remove the hose from the exhaust flap vacuum diaphragm on the rear muffler.
- Connect the (VAS 6213) at the vacuum diaphragm.
- Operate hand vacuum pump.
• Linkage must move upward.
- Vent hand vacuum pump.
• Linkage must move downward.
- If the linkage does not move, make sure it is not stuck and check the vacuum diaphragm for leaks.