Power Steering Line/Hose: Locations
Hose Lines to Reservoir, Hydraulic Fluid Cooler and Return Line Installed Position
Installation Position of the Lines on the Reservoir, Applies to All Engines
- The markings - 2 - on the lines must align with the bars - 1 - on the reservoir.
Installation Position of the Lines on the Hydraulic Oil Cooler, Applies to All Engines
- The markings - 2 - on the lines must align with the markings - 4 - on the hydraulic oil cooler.
• Counterhold the pipes when connecting the lines.
- Secure the clamps - 3 - on the markings - 1 -.
Installation Position on the Return Line Connection, Applies to All Engines
- The marking - 3 - on the line - 5 - must align with the marking - 2 - on the pipe - 1 -.