Heating Performance - With Manually Regulated A/C System
Heating Performance - With Manually Regulated A/C System
Test Requirements
• Coolant circuit has been bled according to specifications.
• All air guides, covers and seal OK and properly installed.
• Air flow through dust and pollen filter not obstructed by dirt.
• Engine is warm.
• The A/C control module (J301) DTC memory was checked and erased, basic setting was performed using Vehicle diagnosis, testing and information system (VAS5051B) in "Guided Fault Finding" function.
• Vehicle not exposed to sunlight
Heating Performance, checking
- Close hood.
- Close doors, windows and sun roof.
- Initiate a Guided Fault Finding on the A/C system using Vehicle diagnosis, testing and information system (VAS5051B) in "Guided Fault Finding" function.
- Open all dash panel vents.
- Start the engine and let it run for a few minutes with maximum cooling output. The A/C compressor is switched on, the indicator lamp in the AC button comes on and the temperature rotary switch is turned all the way to "cold".
- Set the air flow direction to "instrument panel vents" via the air distribution rotary switch.
- Set speed 4 on fresh air blower rotary switch.
- Measure temperature of the air flowing out of left and right instrument panel vents using a thermometer.
- Compare the measured values with the displayed measured value from the evaporator vent temperature sensor (G263). The measured values may not be smaller and after 5 minutes be greater than maximum 3 °C, than the value of the evaporator vent temperature sensor.
Target values:
• Temperature maximum 12 °C, depending on ambient temperature, the difference between the measured values is less than 3 °C.
- Set the highest possible temperature (temperature rotary switch turned all the way to "warm").
- Measure temperature of the air flowing out of left and right instrument panel vents using a thermometer.
Specified Values
• Temperature increases to greater than 55 °C at an engine temperature of approximately 90 °C, deviation between the left and right side is less than 8 °C.
- Set the lowest possible temperature (turn the temperature rotary switch all the way to "cold").
- Measure temperature of the air flowing out of left and right instrument panel vents using a thermometer.
Specified Values
• Temperature decreases within 5 minutes to less than 12 °C depending on ambient temperature.
If the specified values are not reached, check the following:
- Ventilation of coolant circuit.
- Incorporation of heater core for heater in A/C unit into coolant circuit.
- Activation and function of temperature regulator door motor (V68) , check using Vehicle diagnosis, testing and information system (VAS5051B) in "Guided Fault Finding" function.
- Foam seal on heater core for heater of A/C unit. Refer to=> [ Heater Core ] Heater Core.
- Function of temperature doors in air distribution housing. Refer to=> [ Air Routing and Distribution in Passenger Compartment ] Air Routing and Distribution In Passenger Compartment.
- Coolant regulator (engine coolant may not warm properly if regulator is malfunctioning).