Crankshaft, Measuring Axial Play
Crankshaft, Measuring Axial Play
Special tools, testers and auxiliary items required
• Universal Dial Gauge Mount (VW 387)
• Dial Gauge 0-10 mm (VAS 6079)
Procedure
- Attach the (VAS 6079) together with (VW 387) to cylinder block and set indicator against crankshaft counterweight.
- Press crankshaft against dial gauge by hand.
- Set dial gauge to "0".
- Press crankshaft off dial indicator and read the value.
Axial clearance:
• New: 0.07 to 0.23 mm.
• Wear limit: 0.30 mm.