Refrigerant Lines For Condenser, Removing and Installing
Refrigerant Lines For Condenser, Removing And Installing
Disconnecting
- Discharge refrigerant circuit.
- Remove noise insulation.
- Remove entire front bumper.
- Remove bolts - A - (tightening torque 20 Nm).
- Remove refrigerant lines from condenser.
NOTE: Seal open lines and connections at condenser with suitable caps (to prevent dirt and moisture).
Installing
Install in reverse order, paying attention to the following:
- After attaching, check routing of refrigerant lines - A -. They must be inserted in brackets - B - provided and not make contact with other components.
- Replace O-rings - B - and - C -; for version.
- Check type of seal at connections and refrigerant lines (must be designed for same type of seal).
- Evacuate and recharge refrigerant circuit.