Primary Connector With Special Connector Systems
Primary Connector With Special Connector Systems
Procedure
NOTE: If necessary, housing securing mechanisms (secondary locks) must be released or removed using specified tool before releasing the contacts.
Faston contacts:
- Guide release tool (that fits terminal housing) into release channel on terminal housing - arrow -.
- Grasp contact at wire and push gently into terminal housing.
NOTE: By pushing contact in direction of terminal housing, contact retaining tabs are lifted off the housing shoulder and can be released using release tool.
- At the same time, push release tool in direction of terminal housing and pull released contact out of terminal housing - arrow -.
- Remove release tool after removing contact from housing.
GT 150/280 contacts:
- Guide release tool (which fits terminal housing) under retaining tab into terminal housing.
- Push tool into terminal housing until it stops - arrow -.
- Contact is ejected from the terminal housing.
- Remove release tool after removing contact from housing.
Contacts without retaining tabs:
- Insert release tool under retaining tab of terminal housing.
- Push release tool through until it stops by gently lifting - arrow -.
- Contact is ejected from terminal housing.
- Remove release tool after removing the contact from housing.