Refrigerant Circuit, Charging With A/C Service Station
Refrigerant Circuit, Charging With A/C Service Station
NOTE:
- The entire refrigerant charge can be added to either the high or low-pressure side.
- The work procedure is always to be performed as described in the operating instructions for the A/C service station.
- Before pouring in refrigerant, correct quantity of refrigerant oil.
- Switch off ignition.
- Evacuate refrigerant circuit using A/C service station.
- Screw out handwheel at quick-release coupling adapter (to close it).
- Allow refrigerant to flow into charging hose.
- Take charging cylinder reading.
- Screw in handwheel at quick-release coupling adapter (to open it) and charge with the specified quantity of refrigerant.
- Switch off A/C service station.