Misfire Recognition, Checking
Misfire Recognition, Checking
Special tools, testers and auxiliary items required
• (VAS 5051) with (VAS 5051/1)
Work sequence
- Connect Vehicle Diagnostic, Testing and Information System (VAS 5051) or (VAG1551) tester and select control module for engine electronics 1 by inserting address word 01. Refer to => [ VAS5051, Connecting and Selecting Functions ] VAS 5051, Connecting and Selecting Functions. Engine must be running at idle for this test.
Indicated on display
Rapid data transfer HELP
Select function XX
- Press buttons 0 and 8 to select " Read Measuring Value Block" function 08 and press Q button to confirm input.
Indicated on display
Read Measuring Value Block Q
Input display group number XXX
- Press buttons 0, 1 and 4 to input "display group number 14" and press Q button to confirm input.
Indicated on display
Read Measuring Value Block 14 ->
- Check misfire detection.
If specified value is reached:
- Press -> button.
Indicated on display (function selection):
Rapid data transfer HELP
Select function XX
If specified value is not obtained:
- To switch to display group 015 press s button.
Checking misfire recognition of the individual cylinder
Display on (VAS 5051):
- Check misfire recognition in display zones - 1 - to - 4 -.
- To switch to display group 016 press arrow button.
Display on (VAS 5051):
- Check misfire detection in display zones - 1 - and - 4 -.
- Exit function "08 - Read measured value block" by pressing arrow button.
Evaluating display groups 014, 015 and 016, Display field 3: