Throttle Valve, Checking
Throttle Valve, Checking
Requirements
• An original equipment air filter must be installed and it must be OK.
• Intake air guide OK.
• Fuel pressure OK.
• Tank ventilation OK.
• Fuel injectors OK.
• Coolant temperature > 80 °C.
• Oxygen sensor adaptation values and control OK.
Work procedure
Checking oxygen sensor adaptation values and control
Work sequence
- Connect tester (VAS 5051) and select vehicle system "01 - Engine electronics". Refer to => [ VAS5051, Connecting and Selecting Functions ] VAS 5051, Connecting and Selecting Functions Engine must run at idle during this.
Display on (VAS 5051)
- In selection - 1 -, click on the diagnostic function " 04 - Basic Setting".
Display on (VAS 5051):
1. Enter display group
Max. input value = 255
- Select function "032" in button field - 2 - for " display group number 032" and press Q button to confirm input.
Display on (VAS 5051):
- Check specified value in display field - 2 -.
Work sequence
- Disconnect electrical harness connector from Mass Air Flow (MAF) sensor.
- Connect tester (VAS 5051) and select vehicle system "01 - Engine electronics". Refer to => [ VAS5051, Connecting and Selecting Functions ] VAS 5051, Connecting and Selecting Functions Engine must run at idle during this.
Requirement
• Engine running at idle select "address word" 01 and " 04" the "Initiate Basic Setting" function.
Display on (VAS 5051):
1. Enter display group
- Enter "107" in button field - 2 - for " display group number 107" and press Q button to confirm input.
Display on (VAS 5051):
- Check indication in display field - 4 -.
If specified value "System OK" is obtained in display field 4:
- Click on arrow button
- Re-connect Mass Air Flow (MAF) sensor.
- For further fault-finding, perform the next test step in the DTC table.
If specified value "System OK" is not obtained in display field 4:
- Click on arrow button
- Clean air guide in throttle valve control module using a lint-free cloth and methylated spirits.
- Adapt throttle valve control module. Refer to => [ Throttle Valve Control Module, Adapting ] Throttle Valve Control Module, Adapting.
- Repeat test sequence: Oxygen sensor control-short trip, measuring value block 107 in Basic Setting 04.
- Re-connect MAF sensor.
- Erase DTC memory. Refer to => [ DTC Memory, Erasing ] DTC Memory, Erasing.
- Perform a road test. Observe safety precautions. Refer to => [ Safety Precautions ] Multiport Fuel Injection.