ABS/ESP ITT Mark 60
Sensor for transverse acceleration -G200- and Sender for rotation rate -G202- (vehicles up to approx. 08.01), removing and installing
Work procedure
- Remove storage compartment on driver's side.
- Unplug electrical connectors (arrows) on senders -G200-/-G202-.
- Remove bolt -1- and remove mounting bracket for senders --G200-/-G202-.
Removing and installing sender for rotation rate -G202-
- Remove nuts -a- and remove sender for rotation rate -G202- -1-.
- To install: insert sender for rotation rate -G202- into mounting bracket and align straight before tightening.
Note:
- The sender for rotation rate is sensitive to shocks or impact.
- Do not install a sender which has dropped to the ground otherwise proper operation is not ensured.
Removing and installing sensor for transverse acceleration -G200-
- Use screwdriver to pry mount -1- off sensor for transverse acceleration -G200- -2- and remove sender.
- To install: insert sensor for transverse acceleration -G200- -1- in holder.
- Installation position: sloping side (arrow) of sensor for transverse acceleration -G200- must face mount -2-.
- Slip mount over sensor for transverse acceleration -G200- until it engages with a click.
Note:
- The sensor for transverse acceleration is not resistant to shocks or impact.
- Do not install a sender which has dropped to the ground otherwise proper operation is not ensured.
Installing
The remaining installation steps are carried out in the reverse sequence; note the following points:
- Initiate basic setting for sensor for transverse acceleration -G200- and sender for rotation rate -G202-. Adjustments
Tightening torques