Headlamps, Service Preparation - From 11.04
Headlamps, Service Preparation - From 11.04
The following engine-dependent procedures are required in order to replace certain headlamp bulbs.
Preparation - vehicles with 1.8L 4-cylinder Turbo engine
CAUTION:
- Switch off all electrical consumers.
- Switch ignition off and remove ignition key.
Procedure
- Remove right engine cover -1 -.
- Remove screws - arrows -.
- Remove Evaporative Emission (EVAP) Canister Purge Regulator Valve 1 N80 - 1 - at air duct.
- Remove air duct - 2 -.
- Disconnect electrical connections:
1. at Evaporative Emission (EVAP) Canister Purge Regulator Valve 1 N80
2. at Mass Air Flow (MAF) SensorG70
3. at Wastegate Bypass Regulator Valve N75
- Disconnect hoses - 4... 7 -.
- Disconnect hose leading to secondary air pump.
- Set aside wiring.
- Release fasteners at air cleaner housing - 8 -.
- Remove air cleaner housing.
NOTE: The vacuum line leading to combination valve for secondary air is clipped onto the underside of the air intake hose.
Install in reverse order of removal.