Right Footwell Vent Temperature Sensor G262, Removing and Installing
Right Footwell Vent Temperature Sensor G262, Removing And Installing
- Remove operating and display module, Climatronic Control Module J255.
- Reach through opening for operating and display module, Climatronic Control Module J255 and disconnect connector - A-.
- Give Right Footwell Vent Temperature Sensor G262 -B - approx. 90 degrees turn in direction of arrow.
- Pull Right Footwell Vent Temperature Sensor G262 out of air conditioner.
NOTE: observe arrangement of connectors to both sensors ( Left Footwell Vent Temperature Sensor G261 and Right Footwell Vent Temperature Sensor G262 to avoid interchange).