With Generic Scan Tool
Secondary Air Injection (AIR) System, Checking For Proper Seal
- Check the connection pipes and hoses between Secondary Air Injection (AIR) pump motor and combination valve for proper seal.
- Check hoses and hose connections for secure seating.
- Check combination valve for Secondary Air Injection (AIR) system for proper seal.
Final procedures
After repair work, the following work steps must be performed in the mentioned sequence:
1. Check DTC memory. Mode 3: Check DTC Memory
2. If necessary, erase DTC memory Mode 4: Reset/Erase Diagnostic Data.
3. Generate readiness code Readiness Code, Generating.
- End diagnosis and switch ignition off.