Readiness Code Reading
Read Readiness Code
Test sequence
- Connect the vehicle diagnostic, testing and information system VAS 5051, and select the vehicle system "01 - Engine electronics" from the menu. When doing this the engine should be idling. Connecting VAS 5051/VAG1551 Scan Tool
Display on VAS 5051:
- Select diagnosis function "08 - Read data block" from the menu -1-.
Display on VAS 5051:
1 - Enter display group
(figures up to 255)
- Using the keypad -2-, enter "086" for "Display group number 086" and confirm entry with Q button.
Display on VAS 5051:
- Check readiness code in display zone -1-.
- Specification: 0 0 0 0 0 0 0 0
Display Group 086:
If the specification "0 0 0 0 0 0 0 0" is attained:
- Press the <- button.
- To make sure, check DTC memory(no faults should be stored).
If the specification is not attained:
- Generate readiness code Readiness Code, Generating