SID: Distance Until Next Service (Adaptation, Cluster Replaced)
SID: Distance Remaining Until Next Inspection Service (adaptation After Replacing Instrument Cluster)
This function is used after replacing the instrument cluster to enter the distance remaining before the next Inspection Service is due.
Indicated on display:
Rapid data transfer HELP
Select function XX
- Press buttons -1- and -0- and confirm input with Q button.
Indicated on display:
Adaptation
Enter channel number XX
- Press buttons -4- and -0- to access "channel 40".
- Press -Q- button to confirm input
Indicated on display: for new instrument cluster:
Channel 40 Adaptation 1 ->
<-1 3->
The distance remaining before the next Inspection Service is due must be transferred from the old instrument cluster (e.g. 5000 km = adaptation value 50).
NOTE:
- The distance can only be entered in steps of 100 km (62 mi.). Accordingly, the readout on the display will also be in steps of 100 km (62 mi.).
- The entered value is counted upward from 0 to 15000.
- Input values when replacing instrument cluster.
- The number can only be entered directly via the button pad on the scan tool.
- If an incorrect value is entered the adaptation function will be terminated and must be re-started.
- Press -> button.
Indicated on display:
Channel 40 Adaptation 0
Enter adaptation value XXXXX
- Enter required value (noted from old unit) via button pad on scan tool, filling in the initial spaces with "O."
Example:
Distance remaining: 5000 km
Input value: 00050
Indicated on display (example only):
Channel 40 Adaptation 0 Q
Enter adaptation value 00050
- Press -Q- button to confirm input
Indicated on display:
Channel 40 Adaptation 50 Q
<-1 3->
- Press -Q- button to confirm input
Indicated on display:
Channel 40 Adaptation 50 Q
Store changed value?
- Press -Q- button to confirm input
Indicated on display:
Channel 40 Adaptation 50 ->
Changed value is stored
- Press -> button to terminate adaptation of service interval display.