Oil Grade, Adaptation
Oil Grade, Adaptation (where Applicable)
Indicated on display:
Rapid data transfer HELP
Select function XX
- Press buttons -1- and -0- and confirm input with Q button.
Indicated on display:
Rapid data transfer Q
10 - Adaptation
- Press -Q- button to confirm input.
Indicated on display:
Adaptation
Enter channel number XX
- Press buttons -4- and -5- to access "channel 45".
- Press -Q- button to confirm input.
NOTE:
- Oil used must be re-adapted after each service.
- The adaptation value can be set from 1-4. Attached to each value from 1-4 is a max distance (channel 43) and a maximum time (channel 44).
- The value entered for the corresponding engine variation must correspond to value of table.
- Confirm maintenance intervals applicable to vehicle.
Indicated on display:
Channel 45 Adaptation 1 ->
Oil grade < -1 3->
- Press -> button.
Indicated on display:
Channel 2 Adaptation 1
Enter adaptation value XXXXX
- Required value via scan tool button pad, filling in the initial spaces with "O".
Input value: e.g. 2
Entry via keypad: 00002
Indicated on display (example only):
Channel 45 Adaptation 1 Q
Enter adaptation value 00002
- Press-Q- button to confirm input.
Indicated on display:
Channel 45 Adaptation 2 Q
Oil quality < -1 3- >
- Press -Q- button to confirm input.
Indicated on display:
Channel 45 Adaptation 2 Q
Store changed value?
- Press -Q- button to confirm input.
Indicated on display:
Channel 45 Adaptation 2 ->
Changed value is stored
- Press -> button to terminate adaptation of oil grade.