Recirculation Flap Motor -V113-
Recirculation Flap Motor -V113-, Removing And Installing
NOTE: This positioning motor actuates the fresh air/recirculating air flap.
- Remove glove box
- Recirculation Flap Motor -V113-, removing.
- Disconnect harness connector -A-.
- Remove bolt -B-.
NOTE: When removing screw -B-, if necessary reach the bolt from underneath in the recirculating intake area.
- Remove bolts -C-.
- Remove positioning motor.
Notes for installation:
- After installing, always carry out On Board Diagnostic (OBD) of air conditioning system.
- Install the wiring harness so that it cannot come in contact with any moving parts (e.g. the actuating arm on the positioning motor).
- When installing positioning motor; make sure guiding pin -D- engages properly in lever -E-.