FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

Recirculation Flap Motor -V113-




Recirculation Flap Motor -V113-, Removing And Installing







NOTE: This positioning motor actuates the fresh air/recirculating air flap.


- Remove glove box
- Recirculation Flap Motor -V113-, removing.
- Disconnect harness connector -A-.
- Remove bolt -B-.


NOTE: When removing screw -B-, if necessary reach the bolt from underneath in the recirculating intake area.


- Remove bolts -C-.
- Remove positioning motor.


Notes for installation:
- After installing, always carry out On Board Diagnostic (OBD) of air conditioning system.
- Install the wiring harness so that it cannot come in contact with any moving parts (e.g. the actuating arm on the positioning motor).
- When installing positioning motor; make sure guiding pin -D- engages properly in lever -E-.