Component Tests and General Diagnostics
Performing final control diagnosis
- Connect the scan tool and select engine electronics function.
- Press - button.
- Indicated on display (function selection):
- Press keys O and 3 for "Final control diagnosis" and confirm the entry with the Q button.
- Press the - bottom until the following text appears:
- Indicated on display (function selection):
- Confirm entry with the Q button.
The electric vacuum pump should now run for approximately. 10 sec.
- Remove diagnostic cable from diagnostic connection