Shift Interlock Solenoid: Testing and Inspection
Shift Lock Solenoid -N11O-, checking
Note: This test must be performed if the specified values in the voltage measurement are not reached.
Additional special tools and equipment
- Connector test kit VAG 1594 A
Test sequence
- Remove cover for shift control mechanism
- Disconnect harness connector at Shift lock solenoid -N110 -A-.
- Attach multimeter for resistance measurement between contacts -B-.
^ Specified value: 22.3 ± 1 ohms
If the specified value is not reached
- Replace the shift lock solenoid.