With Generic Scan Tool
Secondary Air Injection (AIR) System, Checking For Proper Seal
- Check the connection pipes and hoses between Secondary Air Injection (AIR) pump motor and combination valve for proper seal component overview.
- Check hoses and hose connections for secure seating.
- Check combination valve for Secondary Air Injection (AIR) system for proper seal. Testing and Inspection
Final procedures
After repair work, the following work steps must be performed in the mentioned sequence:
1 - Check DTC memory "Mode 3: Check DTC memory". Diagnostic Mode 3: Check DTC Memory
2 - If necessary, erase DTC memory "Mode 4: Reset/erase diagnostic data". Diagnostic Mode 4: Reset/Erase Diagnostic Data
3 - Generate readiness code. Readiness Code, Generating
- End diagnosis and switch ignition off.