Defroster Flap Motor -V107-, Removing and Installing
Defroster Flap Motor -V107-, Removing And Installing
Removing
- Remove glove compartment:
- Disconnect connector -A-.
- Unscrew bolts -B-.
- Loosen positioning motor from bracket -C-.
- Loosen lever -D-of positioning motor from connection rod -E-
Installing
NOTE: The lever on the positioning motor is color coded, the lever on Central Air Flap Motor -V70- is dark green.
Install all removed parts in reverse order, observe the following while doing so:
- Install the wiring harness so that it cannot come in contact with any moving parts (e.g. the actuating arm of the positioning motor).
- Check DTC memory and erase DTC memory; initiate basic setting
NOTE: The function of the positioning motor can be checked for example: Connect both terminals "5" and "6" in positioning motor connector to 12V (DC), the motor moves in one direction until stop, the direction of rotation changes by reversing B+ and Ground. Use adapter cable for this.