Canister Purge Solenoid: Testing and Inspection

CHECKING THE CANISTER PURGE REGULATOR VALVE

NOTE:For functional testing of Evaporative Emission Control (EVAP) canister purge regulator valve activation, also see On-Board Diagnostics, "Read Measuring Value Block" function 08, Testing and Inspection.

ELECTRICAL CHECK
- Disconnect harness connector on EVAP canister purge regulator valve.

EVAP Canister Purge Regulator Valve Test:




- Measure valve resistance.

Specified Value: 20-28 ohms

If specified values are not obtained:
- Replace EVAP canister purge regulator valve.

CHECKING BATTERY POSITIVE VOLTAGE (B+) SUPPLY
- Disconnect harness connector on valve.

2-Pin Connector:




- Connect VAG 15278 voltage tester between connector terminal 1 and Ground (GND) using cable from VW 1594 test kit.
- Use On-Board Diagnostics (OBD) output diagnostic test mode (DTM) to activate fuel pump relay.

LED must flash.

If LED does not light up:
- Check fuse for EVAP canister purge valve.
- Check continuity in wiring from terminal 1 of connector on EVAP canister purge regulator valve to circuit breaker using wiring diagram.

Specified Reading: maximum 0.5 ohms.

- Check fuel pump relay and activation.

CHECKING EVAP CANISTER PURGE REGULATOR VALVE ACTIVATION

- Connect voltage tester VAG 1527 or equivalent to EVAP canister purge regulator valve connector terminals 1 (B+) and 2 using adapters from VW 1594 connector test kit.
- Use DTM to activate EVAP canister purge regulator valve.

LED must blink.

If LED does not blink or lights up continuously:
- Connect VAG 1598/19 test box to ECM wiring harness. Refer to Computer and Control Systems, System Diagnosis, VAG 1598 Pin Out Box Connecting.
- ECM is not connected.




If LED lights up continuously:
- Check wiring for short circuit to GND between valve connector terminal 2 to test box socket E12 (GND).

If LED does not blink:
- Check wiring for continuity between connector terminal 2 and test box socket E12.

Specified Reading: maximum 1.0 ohm

- If necessary, eliminate open circuit or short circuit to GND between EVAP canister purge regulator valve connector terminal 2 and ECM connector -D- terminal 1.

If there is no open circuit or short circuit:
- Replace ECM.