Air Injection Pump: Service and Repair
REPLACEMENT PROCEDURE
- Remove noise insulation panel (undertray).
- Disconnect horn with bracket.
- Remove bracket -1-.
- Disconnect wiring -2-.
- Disconnect secondary air injection pump harness connector.
- Open clamp sleeve -3- for secondary air injection pump, and remove pump.
- Installation is the reverse sequence of removal.
NOTE: During installation, rubber plug -4- must be placed in the hole in the bracket provided for it.