Read Measuring Block Value Overview
- Connect VAG1551 scan tool and insert the "Transmission Electronics" address word 02, and advance through program until "Select function XX" is displayed. Connecting and Operating VAG 1551 Scan ToolIndicated on display:
Rapid data transfer HELP
Select function XX
- Press buttons -0- and -8- to select "Read Measuring Value Block" function 08.
Indicated on display:
Rapid data transfer Q
08 - Read Measuring Value Block
- Press -Q- button to confirm input.
Indicated on display:
Read Measuring Value Block
Input display group number XXX
- Input display group number.
Example: Press -0-, -0- and -1- for display group no. 001
- Press -Q- button to confirm input.
Indicated on display:
Read Measuring Value Block 1 ->
1 2 3 4
NOTES:
^ Measuring values are displayed in four display fields (using physical units where possible and appropriate).
^ Values in individual display fields, refer to Overview Chart.
^ If the printer is switched on, the current message from the display is printed.