The A/C Condenser/Radiator Fans Do Not Run at High Speed, But Do Run at Low Speed
The A/C condenser/radiator fans do not run at high speed, but do run at low speed
Probable cause: Malfunction in the fan high speed circuit(s)
Do the following troubleshooting as needed:
A/C condenser fan high speed circuit troubleshooting A/C Condenser Fan High Speed Circuit Troubleshooting
Radiator fan high speed circuit troubleshooting Radiator Fan High Speed Circuit Troubleshooting (Without Keyless Access System)
Also check for
Climate control DTCs Initial Inspection and Diagnostic Overview
Also check for
Powertrain DTCs Initial Inspection and Diagnostic Overview
Also check for
Blown fuse on the fan circuit:
Also check for
Without SH-AWD and M/T, No. 3-3 (SUB FAN) (30 A)
Also check for
A/T with SH-AWD, No. 3-2 (SUB FAN) (40 A)
Also check for
No. 3-5 (MAIN FAN) (30 A, without SH-AWD and M/T),(40 A, A/T with SH-AWD)
Also check for
Poor ground at G301
Also check for
Poor or loose connections at the terminals