MIL Stays On
Part 1 Of 2:
Part 2 Of 2:
NOTE:
- When there is no Diagnostic Trouble Code (DTC) stored, the MIL will stay on if the SCS service connector is connected and the ignition switch is ON (II).
- If this symptom is intermittent, check for:
- An intermittent short in the wire between the PCM (A10) and the service check connector
- An intermittent short in the wire between the PCM (A18) and the gauge assembly
- See the OBD-II scan tool or Honda PGM Tester user's manuals for specific operating instructions.