Deceleration Lock-Up
DECELERATION LOCK-UPLock-up Control Solenoid Valve A: ON Lock-up Control Solenoid Valve B: Duty Operation (ON OFF)
The TCM switches solenoid valve B on and off rapidly under certain conditions. The slight lock-up and half lock-up regions are maintained so as to lock the torque converter properly.
NOTE: When used, "left" or "right" indicates direction on the flowchart.